Zhechang Technology
Battery Monitoring Display Host ZC-H3.0

Online automatic monitoring of internal resistance and voltage of single battery, battery terminal voltage, charge & discharge current and temperature, data collection fast and accurate,It can record the battery charging and discharging process to ensure the accurate discrimination of the battery.

Description

Feature:

1. Online automatic monitoring of internal resistance and voltage of single battery, battery terminal voltage, charge & discharge current and temperature, data collection fast and accurate,It can record the battery charging and discharging process to ensure the accurate discrimination of the battery.

2.Warning functions: internal resistance overrun, voltage overrun, temperature overrun, voltage average difference overrun, etc.,Alarm threshold by setting.

3.Automatic storage of alarm information and single battery internal resistance, voltage, charge and discharge current, temperature, discharge data and so on.

4.Support SD card data storage function, up to 32G.

5.Communication methods: RJ45, RS485, CAN,Suitable for different systems.

6.Real-time data query function, historical data query function, alarm data query function, operation parameter setting function.

Zhechang BMS12D 12V UPS Smart Lead Acid Battery Monitor Battery online Monitoring System

 Parameter:

ModelZC-H3.0
CPUTI ARM platform, Cortex A8 kernel
Operating systemLinux
Running memory512M
Data memory256mb
SD card storage32GB
Power supplyDC 24V
Static discharge currentMatch the discharge load according to the requirement
Internal resistance measurement accuracy±(2.5%+25μ Ω )
Voltage accuracy±0.2%
Current  accuracy±1%
Temperature accuracy± 0.5℃
Test battery numberMax  400 units ×4 units
Data recording interval15s(online operation monitoring/static discharge detection state)
Internal resistance test patrol interval30s (It can be setting)
LCD resistance touch7 '800×480 TFT
Interface1*100M LAN (RJ45), 2*CAN, 2*RS485, 2*RS232, 2*USB HOST
Graphical user interfaceQtE (Qt/Embedded)
Query ModeThe scene panel query mode, the remote computer query mode
Control modemicrocomputer automatic control, manual control or remote computer control
Alarm modesound and light alarm, and display alarm content, fault output node is closed
Insulation resistance500M 1500VDC
Power frequency withstand voltage1500VAC
Working environment ambient temperature -10 ~ +55℃
Relative humidity< 95% (no condensation)
Ambient magnetic field< 400A/m
External dimensions210.26×140.26×31.2mm
Weight500g

Contact

Feedback

TOP