Online automatic monitoring of internal resistance and voltage of single battery, battery terminal voltage, charge & discharge current and temperature, data collection fast and accurate,It can record the battery charging and discharging process to ensure the accurate discrimination of the battery.
Feature:
1. Online automatic monitoring of internal resistance and voltage of single battery, battery terminal voltage, charge & discharge current and temperature, data collection fast and accurate,It can record the battery charging and discharging process to ensure the accurate discrimination of the battery.
2.Warning functions: internal resistance overrun, voltage overrun, temperature overrun, voltage average difference overrun, etc.,Alarm threshold by setting.
3.Automatic storage of alarm information and single battery internal resistance, voltage, charge and discharge current, temperature, discharge data and so on.
4.Support SD card data storage function, up to 32G.
5.Communication methods: RJ45, RS485, CAN,Suitable for different systems.
6.Real-time data query function, historical data query function, alarm data query function, operation parameter setting function.
Parameter:
Model | ZC-H3.0 |
CPU | TI ARM platform, Cortex A8 kernel |
Operating system | Linux |
Running memory | 512M |
Data memory | 256mb |
SD card storage | 32GB |
Power supply | DC 24V |
Static discharge current | Match the discharge load according to the requirement |
Internal resistance measurement accuracy | ±(2.5%+25μ Ω ) |
Voltage accuracy | ±0.2% |
Current accuracy | ±1% |
Temperature accuracy | ± 0.5℃ |
Test battery number | Max 400 units ×4 units |
Data recording interval | 15s(online operation monitoring/static discharge detection state) |
Internal resistance test patrol interval | 30s (It can be setting) |
LCD resistance touch | 7 '800×480 TFT |
Interface | 1*100M LAN (RJ45), 2*CAN, 2*RS485, 2*RS232, 2*USB HOST |
Graphical user interface | QtE (Qt/Embedded) |
Query Mode | The scene panel query mode, the remote computer query mode |
Control mode | microcomputer automatic control, manual control or remote computer control |
Alarm mode | sound and light alarm, and display alarm content, fault output node is closed |
Insulation resistance | 500M 1500VDC |
Power frequency withstand voltage | 1500VAC |
Working environment ambient temperature | -10 ~ +55℃ |
Relative humidity | < 95% (no condensation) |
Ambient magnetic field | < 400A/m |
External dimensions | 210.26×140.26×31.2mm |
Weight | 500g |